Inspector TWAIN Report
Manufacturer: | Eastman Kodak |
Product Family: | Document Imaging |
Product Name: | KODAK Scanner: i4000 |
Product Version: | 10.23 |
Information: | KDS v10.23.2 2010/06/16 |
Country: | Usa |
Language: | EnglishUsa |
TWAIN Protocol: | 2.0 |
Supported Groups: | 1073745923 |
|
Compatibility Score: | 99 out of 100
|
Errors: | 37 |
TwainDirect:
-
Certifiable: none
-
Compatible: none
Resolution Information:
- Minimum Value: 100
- Maximum Value: 600
Transfer Methods:
- TWSX_NATIVE
- TWSX_FILE
- TWSX_MEMORY
Error List:
- MissingMandatoryOperation: MSG_QUERYSUPPORT did not contain TWQC_RESET, which is required for CAP_AUTOFEED.
- InvalidContainer: Invalid container for CAP_AUTOSCAN. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_CAMERAENABLED. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_CAMERASIDE. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_DUPLEXENABLED. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_FEEDERENABLED. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_INDICATORS. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_LANGUAGE. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_PRINTER. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for CAP_PRINTERENABLED. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_AUTOMATICBORDERDETECTION. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_AUTOMATICDESKEW. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_AUTOMATICROTATE. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_BITDEPTH. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_BITDEPTHREDUCTION. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_BITORDER. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_BITORDERCODES. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_COMPRESSION. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_CONTRAST. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_EXTIMAGEINFO. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_FRAMES. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_HALFTONES. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_IMAGEFILEFORMAT. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_IMAGEFILTER. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_NOISEFILTER. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_OVERSCAN. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_PIXELFLAVOR. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_PIXELTYPE. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_PLANARCHUNKY. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_ROTATION. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_SUPPORTEDSIZES. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_UNDEFINEDIMAGESIZE. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_UNITS. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_XFERMECH. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_XRESOLUTION. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for ICAP_YRESOLUTION. The container for MSG_RESET must match the container for MSG_GETCURRENT.
- InvalidContainer: Invalid container for MSG_GET with CAP_PRINTERINDEX.